Vue de la page 0
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 02/08/13
Special Application Fuses
PICO
®
259-UL913 Series Intrinsically Safe Fuse for Hazardous Locations
PICO
®
259-UL913 Series Intrinsically Safe Fuse
Baseefa
Description
Agency Approvals
Agency Agency File Number
Baseefa
Baseef02ATEX0071U
IECEx BAS 10.0098U
E10480
(UL 913)
E358130
Electrical Characteristics for Series
Features
Applications
% of Ampere
Rating
Opening Time
100% 4 Hours, Minimum
200% 5 Seconds, Maximum
Hermetically sealed
62mA - 5A range options
Designed to operate
within hazardous
environments
Meet certification for use
within intrinsically safe
apparatus for applications
such as gas plants,
petrochemical, mine, and
processing industries
Electrical Specifications by Items
Schedule of limitations:
1) The fuse must be so mounted that creepage and clearance distances aren’t impaired in any way.
2) The fuse is suitable for use in intrinsically safe equipment for voltages not exceeding 190V peak.
3) Maximum surface temperature rise at 170% rated current ≤750mA=40ºC, 1A=55ºC, 3A=118ºC and 5A=135ºC.
Ampere
Rating
(A)
Interrupting Rating
Nominal
Cold Resistance
(Ohms)
Nominal
Melting
I
2
t (A
2
Sec.)
Nom
Voltage
Drop
(mV)
Agency Approvals
Baseefa
UL 913
0.062
50A @ 125 VAC
300A @ 125 VDC
7. 0 0 0.00016 2.10 x x x
0.125 1.70 0.0012 1.30 x x x
0.250 0.67 0.0095 0.83 x x x
0.375 0.395 0.025 0.81 x x x
0.500 0.302 0.0598 0.78 x x x
0.750 0.175 0.153 0.23 x x x
1. 0 0 0.128 0.256 0.24 x x x
3.00 0.275 1.27 0.131 x x x
5.00
50A @ 125 VAC
300A @ 63 VDC
0.0158 4.14 0.110 x x x
The 259-UL913 Series offers a range of encapsulated fuses
approved under the UL 913 standard for Intrinsically Safe
Electrical Equipment to operate in hazardous locations. Ideal
for use in the oil, gas, mine, chemical, and pharmaceutical
industries, the 259-UL913 fuse was designed to limit the energy
and temperature generated during its operation. In addition
to UL913, these fuses meet ATEx and IECEx requirements.
The fuse design and its encapsulant are suitable for use in
intrinsically safe appartatus for voltage not exceeding 125V rms
(190V peak).
Testing, measuring or processing electronic and
electrical equipment
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Special Application Fuses

© 2013 Littelfuse, Inc.Specifications are subject to change without notice. Revised: 02/08/13Special Application FusesPICO® 259-UL913 Series Intrinsica

Page 2

© 2013 Littelfuse, Inc.Specifications are subject to change without notice. Revised: 02/08/13Special Application FusesPICO® 259-UL913 Series Intrinsica

Commentaires sur ces manuels

Pas de commentaire